McTrack

Time compensation and hysteresis to be applied to a switch on a track.

Name Type Meaning
OnCompensation double The length of time with which a switch is turned on (rising edge) before or after a switching point per track. If the value is positive, the switch-on will be delayed; if the value is negative, the switch-on will be advanced.
OffCompensation double The length of time with which a switch is turned off (falling edge) before or after a switching point per track. If the value is positive, the switch-off will be delayed; if the value is negative, the switch-off will be advanced.
Hysteresis double The distance from a switching point (in positive and negative direction) in which a switch is not turned on or off until the axis has left this area. This can avoid frequent switching around a switching point.